Host interface
|
SAN or direct-attached, 1 Gbps iSCSI and optional 16 Gbps Fibre Channel, 25 Gbps iSCSI or 10 Gbps iSCSI/FCoE
|
|
|
Supported drives
|
3.5-inch disk drives:
-
4 TB, 6 TB, 8 TB, 10 TB and 12 TB 7.2k nearline SAS disk
2.5-inch disk drives:
-
600 GB and 900 GB 15k SAS drive
-
600 GB, 900 GB, 1.2 TB, 1.8 TB and 2.4 TB 10k SAS disk
-
2 TB 7.2k nearline SAS disk
2.5-inch flash drives
-
400 GB, 800 GB, 1.6 TB, 1.92 TB, 3.2 TB, 3.84 TB, 7.68 TB and 15.36 TB
|
|
RAID levels
|
RAID 0, 1, 5, 6, 10, Distributed
|
|
Maximum drives supported
|
760 per control enclosure; 3,040 per clustered system
|
|
Fans and power supplies
|
Fully redundant, hot-swappable
|
|
Rack support
|
Standard 19-inch
|
|
Management software
|
IBM Spectrum Virtualize software
|
|
Cores per control enclosure/clustered system
|
20/80
|
|
Cache per control enclosure/clustered system
|
64 GB, 128 or 256 GB/up to 1,024 GB
|
|
Advanced features included with each system
|
Virtualization of internal storage, data migration, data reduction pools with thin provisioning, unmap and deduplication
|
|
Additional available advanced features
|
Remote mirroring, Easy Tier, compression, external virtualization, encryption, FlashCopy, IBM Spectrum Control, IBM Spectrum Protect Snapshot
|
|
Warranty
|
Hardware:
-
3-year limited warranty
-
Customer-replaceable units
-
On-site service
-
Next business day between 9 a.m. and 5 p.m.
-
Service upgrades available
Software:
-
Software maintenance agreement available
|
|
Replication services
|
FlashCopy, IBM Spectrum Protect Snapshot, Metro Mirror (synchronous), Global Mirror (asynchronous)
|
|
Dimensions
|
Control enclosures
-
Width: 445 mm (17.5 in.)
-
Depth: 749 mm (29.5 in.)
-
Height: 85 mm (3.35 in.)
|
|
Weight
|
Control enclosures:
-
Drive-ready (without drive modules installed): 31.8 kg (70.1 lb)
-
Fully configured (24 drive modules installed): 36.5 kg (80.5 lb)
|
|
Operating environment
|
Air temperature:
-
Operating: 5°C to – 40°C (41°F to – 104°F) up to 950 m (3,117 ft) above sea level. Above 950 m, de-rate maximum air temperature 1 degree per 175 m
-
Non-operating: 1°C to – 60°C (33.8°F to – 140°F)
Relative humidity:
-
Operating: 8% – 85%
-
Non-operating: 8% – 85%
Electrical power:
-
Voltage range: 100 – 240 V ac
-
Frequency: 50 – 60 Hz
-
Power:
-
|
|
Supported drives
|
For a list of currently supported servers, operating systems, host bus adapters, clustering applications and SAN switches and directors, refer to the IBM System Storage Interoperation Center.
|
|
Independent software vendor (ISV) solutions
|
For a list of high-quality solutions with our partner ISVs, including access to solution briefs and white papers, refer to the ISV Solutions Resource Library.
|
|